Whole House Water Conditioning Systems
Note: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Whole House Water Conditioning Systems
2
21
PURE WATER
Features
•IncreasesthepHofacidic
water
•Eliminatesthecorrosionof
plumbingandfixturescaused
bylowpHwater
•Nomore“greenstain”copper
depositsintubs,toilets,and
sinks
•BettertastingpHbalanced
water
•User-friendlyequipment
•10”diametertanksandlarger
haveadomeholeaccessport
onthetopforcheckingand
addingmedia
•Lowmaintenanceduetoauto-
maticoperation
Media
Thesesystemsuseahighquality
granularcalcite(calciumcarbon-
ate)mediatoaccomplishthe
neutralizationprocess.Aslow
pHwaterflowsdownthrough
themediabeditreactswiththe
calcitemediaanddissolvesit.
ThiscausesthepHofthewater
tomovefromanacidicstateto
aneutralstate.Thisdissolving
ofthecalcitemediawillrequire
calcitetobeaddedtothebed
overtime.
Series Pro SE Control
Valve
Manufacturedfromhigh-tech
materials,theSeriesProSE
controlvalvehasbeenengi-
neeredandtestedtowithstand
theequivalentof27yearsof
uninterrupteddailyuse.Thepro-
prietarydesignfeaturesaTeflon®
coatedpistonthatglidesthrough
aseriesofsealsandspacers.
Thisseal/spacerandpiston
configurationisthemostreliable
designinvalvetechnology.The
valvefeaturesanelectroniccon-
trolforeasyprogramming.
Filter Tank
Featureshighlycorrosionresis-
tantNSFcertifiedfiberglass
tanks
withathermoplasticinner
liner.ThetanksareNSF/ANSI
Standard44or61certified.
Teflon
®
isaregisteredtrademark
ofE.I.duPontdeNemoursand
Companyoritsaffiliates.
Series PWBWCAL
Whole House Acidic Water Neutralizing Systems
Connection Size: 1" (25mm)
Flow Rate: Up to 15 gpm (56 lpm)
Watts Whole House System for increasing the pH of acidic water.
SeriesPWBWCALacidneutralizingsystemaredesignedforresidentialapplicationswithintermittent
flowratesupto15gallonsperminute.Theystopthecorrosionofmetalcomponentsandfixtures
withinaplumbingsystembyneutralizingtheacidicnatureofsupplywaterthathasapHoflessthan
7.Periodicbackwashingofthemediabedcleansitofcapturedimpurities.
PWBWCAL
For additional information, access online literature ES-WQ-PWBWCAL.
MODEL NO. VALVE MINERAL TANK
SIZE
MEDIA CUBIC
FOOT
GRAVEL (LBS.) PEAK SERVICE
FLOW (GPM)
PRESSURE DROP
(PSI)
BACKWASH
(GPM)
FLOOR SPACE
L X W X H
PWBWCAL1 Time Clock 9" X 48" 1 10 5 <15 7 16" X 10" X 55"
PWBWCAL15 Time Clock 10" X 54" 1.5 10 7 <15 7 16" X 11" X 62"
PWBWCAL2 Time Clock 12" X 52" 2 30 10 <15 10 17" X 13" X 60"
PWBWCAL3 Time Clock 13" X 65" 3 40 15 <15 15 18" X 14" X 74"
Acidic Water Neutralizing System
*Note: Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These systems are designed
to treat the domestic water used in a single family dwelling. For irrigation water treatment or higher volume applications please contact your Watts represen-
tative. Peak service flow rates are based on a 15 psi drop.
Optimum service flow rate is specific to water chemistry and will vary.